Yoking YOKING
Products › YJm
YJm Self-priming jet (shallow-well)

YJm Self-Priming Jet Pumps

Self-priming jet pumps for shallow wells, cisterns, and rooftop tank feed.

Power
0.25 – 1.3 kW (0.37 – 1.8 HP)
Flow
up to 4.5 m³/h
Head
up to 55 m

Overview

The YJm series couples a centrifugal impeller with an integrated jet ejector so the pump can self-prime from 9 m in typically 20 seconds — the answer for shallow wells, cisterns, and any installation where the pump is mounted above the water source.

Noryl engineering-plastic diffuser and impeller reduce weight and corrosion risk; brass or stainless-steel upgrade paths are available for potable-water service.

Typical Applications

  • Shallow-well or cistern draw
  • Rooftop tank feed
  • Garden and greenhouse irrigation with intermittent supply
  • Pressure-tank automatic booster sets
  • Installations where the suction pipe tends to admit air

Operating Window

ItemRating
Self-priming liftup to 9 m
Priming time~20 s at full lift
Liquid temp.0 °C to +60 °C
Ambient temp.0 °C to +40 °C
Insulation classF / IP 44

Duty Points

ModelkWHPQ_max (m³/h)H_max (m)
YJm370.250.371.835
YJm600.450.602.445
YJm750.550.752.750
YJm1000.751.003.050
YJm1200.901.203.652
YJm1501.101.504.255
  • Larger flow, non-priming → YCm centrifugal
  • Truly deep wells → submersible WQ or dedicated deep-well pumps

Specifications

Source: Yoking Samplebook: DOMESTIC CENTRIFUGAL PUMP 50HZ

Working Conditions

____
20 秒(满 9 m)
Liquid temperature
0 °C ~ +60 °C
Ambient temperature
0 °C ~ +40 °C
Insulation class
Class F / IP44

Materials of Construction

Pump body
铸铁
Impeller
Noryl(工程塑料)
___
Noryl
Shaft
不锈钢
Bearing
滚珠轴承
Seal
机械密封

YJm

Power
0.25 – 1.3 kW (0.37 – 1.8 HP)
Flow Rate
up to 4.5 m³/h
Head
up to 55 m

Models & Duty Points

Model kW HP Q=0.6Q=1.2Q=1.8 Q max
YJm37 0.25 0.37 352515 1.8 m³/h
YJm60 0.45 0.6 45382817 2.4 m³/h
YJm75 0.55 0.75 50423322 2.7 m³/h
YJm100 0.75 1 5045382818 3.0 m³/h
YJm120 0.9 1.2 5248423322 3.6 m³/h
YJm150 1.1 1.5 5550453727 4.2 m³/h

H values in meters at the listed Q (m³/h). Data read from factory curves — request certified curves for tendering.